Filter Results By:

Products

Applications

Manufacturers

Showing results: 361 - 375 of 481 items found.

  • Ultra-compact Photoelectric Sensor

    EX-20 Ver.2 - Panasonic Industrial Devices Sales Company of America

    Using a single chip optical IC, Panasonic created the powerful EX-20 Ultra-Compact Photoelectric Sensors, which are among the smallest Photoelectric Sensors worldwide and in spite of their miniature size, the Sensors incorporate a sensitivity adjuster. Since a red LED dot light source is used, alignment and confirmation of the sensing position is easy, even if very tiny objects have to be detected.

  • CCD Spectroradiometer

    LMS-8000A/LMS-8000 - Lisun Electronics Inc.

    LMS-8000A/LMS-8000 LED Measurement System is an automated measurement system for identifying the performance of individual LED. It is designed to have a capability of producing any visible spectral distribution, mimicking various light sources in the visible region by feedback control of the radiant power emitted by individual LEDs. This LED test system will be used as a transfer standard for photometric, colorimetric and radiometric applications.

  • Degree of Polarization Meter

    DOP-201 - General Photonics Corp.

    The DOP-201 measures and displays the Degree of Polarization (DOP) of a light source in real time on the front panel display. The instruments incorporates a patented maximum & minimum search technique that accurately measures both low and high DOP. This technique is superior to polarimeter-based methods that are inaccurate at low values of DOP as well as scrambler-based methods which are less accurate at high values of DOP.

  • Complete Testing Solutions

    Sciencetech, Inc.

    System includes a lamp and monochromator for a tunable light source, which is coupled to a high sensitivity source meter with measurement software. This user-friendly system is the most powerful Spectral Response system currently on the market, but its true power is the ease of upgrading from the base PTS-1 to the more powerful PTS-2-QE (Quantum Efficiency) or PTS-3-CPM (Constant Photocurrent Method). Designed for researchers who have limited budgets but want to start work immediately, this allows the ability to do baseline studies until additional funding for the full QE or CPM system becomes available.

  • 2-Wavelength, Polarization-Maintaining WDMs

    Thorlabs, Inc.

    Thorlabs' Fused Polarization Maintaining (PM) Wavelength Division Multiplexers (WDMs) combine two wavelengths of light in PM fiber while maintaining the polarization of the incident light. These WDMs are reversible; they can also be used to split two discrete wavelengths entering the common port into two separate output ports. They are not designed to split the output from a broadband source. PM WDMs are often used for pump / signal applications that incorporate erbium-doped or ytterbium-doped fiber amplifiers. They can be readily customized for a wide variety of applications, enabling rapid design cycles and new project builds. For custom requests, please contact Tech Support.

  • High Voltage Meter

    STME-VM - Statclean Technology (S) Pte Ltd

    This is a High Input Impedance Voltmeter with 70 Gigohm input impedance. Capable of measuring up to DC voltage up to +/-5.5kV with 1.0V resolution over a range of himidity and temperature, the meter measures with better than 1% accuracy without loading the power source. Its compact size and light weight body allows applications in laboratory and field work when powered by battery.

  • Multi-Meter

    TW3207 - Techwin(China) Industry Co., Ltd

    Multi-Meter TW3207 integrates the functions of an intelligent optical power meter module and of a highly stable light source module in one unit which can perform closed-loop tests by incorporating both modules. Individual regimes of operation can also be manually chosen using menu operation to switch functions. A perfect combination to make your optical fiber tests a lot more convenient.

  • MPO Visual Cable Verifier Kit

    KI-TK824 - Kingfisher International

    Kingfisher's unique and innovate MPO Visual Cable Verifier Kit is a quick, versatile and inexpensive way to visually check MPO cable installations and patch leads for polarity and continuity, and overall end face condition. Just connect the source, and view the far end with the microscope to observe the repeating color pattern at the far end. Fiber 1 is easily identified with a winking light.

  • MPO Visual Cable Verifier Kit

    KI-TK812 - Kingfisher International

    Kingfisher's unique and innovate MPO Visual Cable Verifier Kit is a quick, versatile and inexpensive way to visually check MPO cable installations and patch leads for polarity and continuity, and overall end face condition. Just connect the source, and view the far end with the microscope to observe the repeating color pattern at the far end. Fiber 1 is easily identified with a winking light.

  • Non-Contact Type Phase Sequence Indicator

    895 PR - Standard Electric Works Co., Ltd

    ● Protection class: IP40● Non-contact detector clips. No metal contact points to advocate greater safety.● Two functions in one unit : open phase and phase sequence detection.● Designed for checking a wider range of 3-phase power sources.● LED display lights with buzzer indicator. ● Brightness button feature for better visibility in dimly lit areas or sunlight.● Magnetic mounting feature.

  • Fiber Shaker

    MPX-SR3 - Arden Photonics LTD

    Arden’s MPX Modal Explorer makes measurement of Encircled Flux easy, and accurate, and it complies with international standards. But if you are measuring laser-based transmission light sources for multimode systems you may need to use a test jumper assembly and fiber shaker in order to avoid “speckle”. Industry standards (for example IEEE 802.3aq and FOTP– 203) call for the use of a mechanical fiber shaker.

  • Fiber Loss Meter

    Appointech, Inc.

    Testing for loss (also called "insertion loss") requires measuring the optical power lost in a cable (including fiber attenuation, connector loss and splice loss) with a fiber optic light source and power meter (LSPM) or optical loss test set (OLTS.)

  • Portable Optical Power Meter

    CARY-PM300 - UC Instruments, Corp.

    The CARY-PM300 portable Optical Power Meter is a newly designed fiber optic tester,which aims at the installation, engineering acceptance and maintenance of fibernetwork. Combined with CARY-LS300 handheld optical light source, it offers a quickand accurate testing solution on both SM and MM fibers.

  • Random Access Monochromator

    DeltaRAM X - HORIBA, Ltd.

    The patented DeltaRAM™ X microscope Illuminator is the ideal fluorescence illuminator for quantitative intracellular ion research. It utilizes a galvanometer-based Random Access Monochromator (RAM) that can switch between any wavelength in 2 milliseconds. The DeltaRAM™ X is a complete, self-contained, illuminator that includes a power supply, high intensity xenon light source, DeltaRAM™ X monochromator, TTL shutter and flexible liquid light guide. The wavelength position is a simple analog voltage control. All you need to add is a microscope adapter for your fluorescence microscope and a USB or PCI DAC interface depending on the software you will be using to drive the illuminator.

  • Laser Spectroscopic Motor Exhaust Gas Analyzer

    MEXA-ONE-QL-NX - HORIBA, Ltd.

    The MEXA-ONE-QL-NX is an analyzer for the direct, simultaneous real-time measurement of the four relevant nitrogen-containing exhaust gas components NO, NO2, N2O and NH3.The analyzer combines a light source based on the new quantum cascade technology (efficient lasers in the mid-infrared spectral region) with a precisely adjusted dual path cell to measure low concentrations with maximum sensitivity. The detection limit complies with current European legal requirements.Furthermore, the MEXA-ONE-QL-NX offers wide measuring ranges of up to 5000 ppm (for NO). By using extremely narrowband light sources and measuring under reduced pressure the cross-sensitivity to other exhaust gas components can be drastically minimized.The complete measuring system - including filtration - is specifically developed for the measurement of NH3 and thus guarantees a very fast NH3 rise time (T10-T90) of less than 5 seconds. The MEXA-ONE-QL-NX can be operated as a stand-alone analyzer or integrated into the MEXA-ONE software interface for user-friendly and simplified system operation.

Get Help